| IPCP Pro 555Q xi | |||
| Memory | |||
|---|---|---|---|
| SDRAM | 2 GB | ||
| Flash | 8 GB | ||
| Software | |||
| Configuration software | Global Configurator® Plus and Professional | ||
| Programming software | Global Scripter® | ||
| Control apps | Extron Control | ||
| Resource management software | GlobalViewer® Enterprise | ||
| Utilities | Toolbelt, embedded web page | ||
| Hardware user interface | |||
| Hardware | TouchLink® Pro touchpanels, Network Button Panels, or eBUS® button panels | ||
| Ethernet | |||
| Network interface controllers (NICs) | 2: 1 LAN, 1 AV LAN | ||
| Connectors | 2 female RJ-45 connectors | ||
| Data rate | 10/100/1000Base-T, half/full duplex with autodetect | ||
| Protocols | ARP, DHCP, DNS, HTTP (redirect), HTTPS, ICMP, IEEE 802.1X, NTP, SFTP, SMTP, SNMP, SSH, TCP/IP, UDP/IP | ||
| Default settings | |||
| LAN | Link speed and duplex level = autodetected IP address = 192.168.253.250 Subnet mask = 255.255.255.0 Gateway = 0.0.0.0 DHCP = off DNS = 127.0.0.1 | ||
| AV LAN | Link speed and duplex level = autodetected DHCP server = disabled Subnet mask = 255.255.255.0 Gateway = 0.0.0.0 | ||
| DHCP server disabled | IP address = 192.168.254.250 DNS = 127.0.0.1 | ||
| DHCP server enabled | IP address = 192.168.254.1 DNS = 192.168.254.1 Dynamic leased IP address pool = 192.168.254.100 – 192.168.254.149 Maximum lease count = 50 Lease time = 24 hours | ||
| Serial | |||
| Quantity/type | 2 bidirectional RS-232, RS-422, RS-485 (ports 7 and 8) 6 bidirectional RS-232 (ports 1 through 6) | ||
| Connectors | (2) 3.5 mm captive screw connectors, 5 pole (6) 3.5 mm captive screw connectors, 3 pole | ||
| Baud rate and protocol | 300 to 115200 baud (9600 baud = default); 8 (default) or 7 data bits; 1 (default) or 2 stop bits; no parity (default), even, or odd parity | ||
| |||
| Pin configurations | |||
| Serial, 5-pole captive screw | |||
| RS-232 (default) | Pin 1 = Tx, 2 = Rx, 3 = Gnd, 4 = RTS, 5 = CTS | ||
| RS-422 | Pin 1 = Tx-, 2 = Rx-, 3 = Gnd, 4 = Tx+, 5 = Rx+ | ||
| RS-485 | Pins 1 and 2 (tied together) = data-, 3 = Gnd, 4 and 5 (tied together) = data+ | ||
| Serial, 3-pole captive screw | Pin 1 = Tx, 2 = Rx, 3 = Gnd | ||
| Flex I/O | |||
| Quantity/type | 4 analog input or digital input/output (configurable) | ||
| Connectors | (1) 3.5 mm captive screw connector, 5 pole | ||
| Digital inputs | |||
| Input voltage range | 0 to 24 VDC, clamped at +30 VDC | ||
| Input impedance | 29k ohms | ||
| Programmable pullup | 1k ohms to +5 VDC | ||
| Threshold low to high | Programmable range: 100 mV to 24 VDC, default = 2.4 VDC | ||
| Threshold high to low | Programmable range: 100 mV to 24 VDC, default = 0.8 VDC | ||
| Digital outputs | 250 mA sink from 24 VDC max. | ||
| Analog inputs | 12 bit A/D, 0 to 24 VDC | ||
| Pin configurations | 1, 2, 3, 4 = flex I/Os 1, 2, 3, 4; 5 = Gnd | ||
| IR/serial | |||
| Quantity/type | 8 programmable: unidirectional RS-232 (±5 V), or TTL level (0 to 5 V) infrared (carrier and non-carrier) up to 300 kHz | ||
| Connectors | (4) 3.5 mm captive screw connectors, 4-pole | ||
| Baud rate and protocol (RS-232) | 300 to 115200 baud (9600 baud = default); 8 (default) or 7 data bits; 1 (default) or 2 stop bits; no parity (default), even, or odd parity | ||
| Pin configurations | For each port, pin 1 = signal, 2 = Gnd | ||
| IR output carrier frequency | 30 kHz to 300 kHz | ||
| IR learning carrier frequency | 30 kHz to 300 kHz | ||
| IR learning capture distance | 2″ (5.1 cm) to 12″ (30.5 cm) from the front panel | ||
| Relay | |||
| Quantity/type | 8 normally open relays | ||
| Relay control connectors | (4) 3.5 mm captive screw connectors, 4 pole | ||
| Relay control contact rating | 24 VDC, 1 A | ||
| eBUS | |||
| eBUS control ports | (1) 3.5 mm captive screw connector, 5 pole (uses 4 poles) | ||
| eBUS pin configuration | +V = +12 VDC; +S = + signal; -S = – signal; G = ground | ||
| Recommended cable type | Extron STP20-2/1000 or STP20-2P/1000 cable | ||
| Maximum system cable length | 1000 feet (305 meters) sum total for the eBUS system, regardless of topology. Power injection may be required depending on system cabling topology and primary power supply wattage. See the eBUS Technology Reference Guide for details. | ||
| eBUS power output | 12 watts | ||
| Switched DC power output | |||
| Quantity/type | 4 switched 12 VDC outputs | ||
| Connectors | (4) 3.5 mm captive screw connectors, 2 pole | ||
| Power | Maximum 40 watts total | ||
| Power sense | |||
| Range | 0.1 watt to 40 watts | ||
| General | |||
| Power supply | Internal Input: 100-240 VAC, 50-60 Hz | ||
| Power consumption | 68.4 watts 7.3 watts, 100-240 VAC, 50-60 Hz without eBUS or switched 12 VDC output | ||
| Ambient temperature/humidity | Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing | ||
| Cooling | Convection, no vents | ||
| Thermal dissipation | 192.5 BTU/hr 24.9 BTU/hr without eBUS or switched 12 VDC output | ||
| Mounting | |||
| Rack mount | Yes, with optional 1U rack shelf | ||
| Furniture mount | Yes, with optional bracket kit | ||
| Enclosure type | Metal | ||
| Enclosure dimensions | 1.7″ H x 8.7″ W x 10.5″ D (1U high, half rack wide) (43 mm H x 221 mm W x 267 mm D) (Depth excludes connectors.) | ||
| Product weight | 2.4 lbs (1.1 kg) | ||
| Regulatory compliance | CE, C-Tick, c-UL, FCC Class A, ICES, KC, UL, VCCI Complies with the appropriate requirements of RoHS, WEEE | ||
| Product warranty | 3 years parts and labor | ||
| Everlast power supply warranty | 7 years parts and labor | ||
| |||
| |||
The Extron IPCP Pro 555Q xi is a compact, high-performance control processor with a secure, dedicated AV LAN port. It features a Quad Core processor and four times more memory than our IP Link Pro multi-network control processors. It also features advanced security standards and dual Gigabit Ethernet ports, which ensure compatibility with multiple TouchLink® Pro touchpanels, Network Button Panels, and IPL EXP expansion interfaces using a standard network infrastructure. Of the two Ethernet ports, the AV LAN is designed to control local AV devices, and safeguard them from outside intrusion or interference. The IPCP Pro 555Q xi is an ideal choice for controlling multiple devices and control signal types within AV systems requiring an isolated AV network.
The IPCP Pro 555Q xi features a DHCP server for the AV LAN that streamlines system setup and management. It automatically distributes IP addresses and network configuration parameters for the AV devices connected to the local AV LAN. The AV LAN port permits communications from the Ethernet port for remote management and firmware updates for Extron devices, and restricts other Ethernet traffic.
The Extron IPCP Pro 555Q xi can be configured using Global Configurator Plus or Global Configurator Professional software or programmed using Extron ControlScript programming. For enterprise-wide applications, GlobalViewer® Enterprise can provide centralized AV resource monitoring, management, and control over a computer network. The IPCP Pro 555Q xi can be used with Extron LinkLicense®, which further enhances the capabilities of Extron Pro Series control systems.
Features
- Quad-core processor and four times more memory with 2 GB of RAM and 8 GB of Flash — For increased project upload speeds, faster runtime performance, and more sophisticated projects.
- Supports TouchLink Pro touchpanels, eBUS® devices, Network Button Panels, and IPL EXP expansion interfaces
- AV LAN port allows AV devices to be isolated from the corporate network — Enables local control of AV devices connected to this port, while securing this equipment from outside interference or intrusion.
- The LAN port will permit discovery, setup and firmware updates for Extron devices connected to the AV LAN port — Extron PCS, DSP and XTP Configurator allow customers to discover, manage and update Extron devices from the LAN to the AV LAN.
- Supports secure industry standard communications protocols — All IP Link Pro models use industry standard communication protocols, including HTTP (insecure), HTTPS, SSH, SFTP, SMTP, NTP, Discovery Service, DHCP, DNS, ICMP, 802.1X, and IPv4.
- Supports LinkLicense® — Extron LinkLicense unlocks features that add convenience, expand system functionality, and enhance the capabilities of Extron products.
- Six bidirectional RS-232 serial ports with software handshaking — Captive screw serial ports that can control six RS-232 devices.
- Two bidirectional RS-232/RS-422/RS-485 serial ports with hardware and software handshaking — Captive screw serial ports that can communicate with two RS-232/RS-422/RS-485 serially controlled devices.
- Eight IR/Serial ports for one-way control of external devices
- Four Flex I/O ports — Allows for interfacing with other systems in the room.
- Eight relays for controlling room functions — Enables control of lighting, screen settings, and other device functions.
- eBUS port for connecting eBUS button panels and accessories
- Four independently switched 12 VDC outputs — Provides power to low voltage devices to eliminate the need for local power supplies.
- Ethernet monitoring and control on each Ethernet port — Manage, monitor, and control AV devices using a standard Ethernet network.
- Central Deployment - Use the primary control processor to deploy all system files, configurations and programs — Quickly deploy the control system by uploading all project files to the primary control processor. The primary control processor will automatically transfer files to the other touchpanels, control processors and button panels in that system once they come online.
- DHCP server for AV LAN — Automatically distributes IP addresses and network configuration parameters for AV devices connected to the local AV LAN, which streamlines system setup and management.
- Supports popular BMS – Building Management System protocols, such as BACnet, KNX, and DALI — These protocols allow for centralized monitoring and control of mechanical and electrical systems that include HVAC, lighting, power, fire, and security.
- Supports 10/100/1000Base-T
- Supports Ethernet-controllable devices — Allows for control of multiple Ethernet-enabled AV devices such as displays, switchers, and sources.
- Integrated IR learner capability — Captures IR remote codes from a device’s handheld remote control.
- Automatic clock synchronization allows touchpanel to display the accurate time and date
- Supports control system synchronization — Synchronization will allow users to retain and recover the state of their configured endpoints in case of network or power failure.
- Front panel port status indicators
- Multi-level password protection — Allows security to be set based on user roles.
- Fully customizable using Extron control system software — GUI Designer combined with Global Configurator Plus, Global Configurator Professional, or ControlScript programming.
- Library of Pro Series device drivers and modules for use with Global Configurator and ControlScript programming, respectively — Start and execute projects quickly using Extron Global Configurator device drivers and Extron device modules to control various display and source devices, such as projectors, flat-panel displays, and Blu-ray players. Extron offers fully tested Ethernet, serial, and IR device drivers and modules.
- Supports 802.1X Authentication — Provides support for IEEE 802.1X authentication standard for port-based Network Access Control.
- Compact, 1U, half rack width metal enclosure
- Internal Extron Everlast™ power supply — Provides worldwide power compatibility, with high‑demonstrated reliability and low power consumption for reduced operating cost.
- Extron Everlast Power Supply is covered by a 7‑year parts and labor warranty
- TAA Compliant version available — Please inform your local Extron representative if your order requires compliance with TAA regulations.