Product

PPC 25 – Priority Page Controller

Key Features

  • Detects audio signal in a public address system speaker and mutes program audio
  • Designed for use exclusively with Extron products which have remote volume and mute control ports
  • Compatible with 25/70/100 volt and 4/8 ohm public address systems
  • Adjustable time delay from 2 to 8 seconds for restoring audio after a page
  • Eighth rack width, one inch high metal enclosure
Categories: , , Brand:
PPC 25 Priority Page Controller
Control — relay output
   Relay number/type1 latching (on/off)
   Connectors(1) 3.5 mm captive screw connector, 2 pole, normally open
   Contact rating24 V, 1 A
Control — paging input
   Paging sensor connector(1) 3.5 mm captive screw connector, 2 pole
General
   Power input requirements12 VDC, 33 mA
    NOTEA power supply is not included with the PPC 25.  A power supply can be shared with other products.
   Ambient temperature/humidityStorage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
   Mounting
      Rack mountYes
   Enclosure typeMetal
   Enclosure dimensions1.0″ H x 2.2″ W x 3.0″ D (one eighth rack wide)
(2.5 cm H x 5.6 cm W x 7.6 cm D)
   Product weight1.5 lbs (0.7 kg)
   Shipping weight2 lbs (1 kg)
   VibrationISTA 1A in carton (International Safe Transit Association)
   Regulatory compliance
      SafetyCE, CUL, UL
UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release, excluding the power supply; meets UL 60065 for safety
       NOTEThe Priority Page Sensor must be installed in a sealed enclosure such as a metal junction box in order to meet UL 2043 requirements for use in plenum spaces.
      EMI/EMCCE, C-tick, FCC Class A, ICES, VCCI
   Product warranty3 years parts and labor
    NOTESpecifications are subject to change without notice.

The PPC 25 mutes audio during a page from a public address system. The sensor connects to a PA speaker lead and detects current flow when a PA announcement is initiated. The sensor signals the controller to close its output relay which sends a mute signal to the audio device. The output relay can be connected to any Extron product that has a digital input or contact closure mute control, such as the MLC 104 IP Plus MediaLink® Controller, PVS 204SA PoleVault® Switcher, or MPA Series and XTRA™ Series power amplifiers with a 3-pole remote control port.

Note: The PPC 25 and sensor cable are UL 2043 plenum rated, allowing for installation above a drop ceiling. The PPC 25 Sensor assembly must be installed in a sealed enclosure, such as the included metal junction box to meet the plenum rating requirement.

 

Features

  • Detects audio signal in a public address system speaker and mutes program audio
  • Designed for use exclusively with Extron products which have remote volume and mute control ports
  • Compatible with 25/70/100 volt and 4/8 ohm public address systems
  • Adjustable time delay from 2 to 8 seconds for restoring audio after a page
  • Eighth rack width, one inch high metal enclosure
  • Priority Page Sensor and 35' (10.6 m) sensor cable included